C-DOT DSS MAX
I. Fill in the blanks:
1) The destination of Signalling Cables is given in P/Q/R/S/T format. Here, P denotes ……………………………………
2) The MDF Cables used for connecting Subscriber lines consists of 64 pairs divided into …………… bunches of ………………… pairs each.
3) To carry out Exchange Side (Signalling + CODEC) tests of a Subscriber Line, Test Set No: ………………… is used.
4) When one copy of BMS goes faulty in a Base Module, the class of alarm generated is …………………………………
5) The Subscriber priority assigned by the system for CCB-STD line is …………
6) A Trunk Group may be identified by a number between …………… & ………………
7) A trunk circuit is identified by the ………………… designating the port at which the circuit is connected to the Exchange hardware.
8) TGP-CAT may be a number between ……………… and ……………………
9) Not more than ……………… TENs can be added to a TGP by a single command.
10) In a TU, time slot ……………………… is used as HDLC message link with BPU.
11) The Announcement Card (ANNC) provides …………… different stored announcements.
12) TTC is located in Slot No: …………… in TU ……………… in the SBM switch.
13) The 128 terminals in a TU are scanned by the SPC during a period of ……… ms.
14) SCIC card in TSU is similar to TIC card hardware and software-wise.
15) IOP is used as the …………………………………… in C-DOT DSS.
16) IOM consists of two similar switch units, namely, ……………… and …………………
17) Operating System used in IOP is ……………………
18) The Link speed of IOP-BP/AP link is …………………… and that of IOP-IOP link is ………………………
19) The BPU hardware when used in AM is called …………………………… and when used in CM is called …………………………………
20) In SBM configuration, BPU is connected to ………………… , …………………… and ………………………………… through HDLC links.
21) ……………………………… is the message transfer point in Base Module.
22) BP communicates with other processors like TIC, SCIC, TSC, TGA, ANNC, MFC through ……………………………………
23) BMS is housed in ………………………………… frame.
24) In MBM configuration, BPU is connected only to ………………………………………
25) In MBM configuration, IOP and ADP are connected to ………………………………
26) In C-DOT DSS MAX, ……………………… is the basic growth unit.
27) The LCC interfaces up to ……………… subscribers.
28) A Terminal Group (TG) consists of ……………… Terminal Cards.
29) In a TU, there can be a maximum of ……………… Terminal Groups (TG).
30) TIC is an ………-bit microprocessor Controller Card.
31) The two types of analog trunk cards are ……………………… & ……………………………
32) TSU receives …………………… channels from each TU.
33) In APU, ………………… Central Message Switches (CMS) are housed.
34) The I/P supply to PSU-II is …………………… and it generates secondary voltages like ……………… , …………………… , …………………… & ……………………
35) If BMS-0 goes faulty in the Base Module, a ………………… Alarm is generated.
II. Choose the correct answer from the brackets:
1) ………………… is the heart of the SBM. (ANNC/ TIC/ BP)
2) There are ………………… Test Access relays in an LCC. (2/ 4/ 8)
3) A maximum of ……………… Terminal Cards can be provided in a TU. (8/ 16/ 24)
4) The signaling information from the terminations are processed by …………… card. (TIC/ TUI/SPC)
5) A TIC controls ………………… Terminal Groups. (2/ 4/ 8)
6) A maximum of ………………… Digital Trunk Systems can be provided in a DTU. (4/ 8/ 16)
7) A maximum of ………… MFC cards can be provided in C-DOT SBM RAX. (4/ 3/ 8)
8) All the tones required for the Exchange are generated by ………………… card. (ANNC/ MFC/ TGA)
9) …………………………… acts as a Message Transfer Point between BP and different controllers. (BP/ BMS/ MU)
10) The Master Controller in the SBM is ………………… (BPU/ TSU/ TIC)
11) The maximum concentration permissible in C-DOT MAX is …………………………… (3:1/ 4:1/ 8:1)
12) The OOD terminal is connected to the ……………… (BP/ TS/ IOP)
13) When one of the IOPs goes out of service, …………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
14) When ANNC goes out of service, …………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
15) When any PSU card failure happens, ………………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
16) When Battery-Low condition is encountered, …………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
17) To find out the status of all Switch Units (SWU) in the system, ……………………… command is used.
18) In BPU and TSU, the PSUs used are of type …………………… (I/ II/ III)
19) From each LCC slot, ……………………… pairs of wires are to be extended to MDF. (8/ 16/ 24)
20) In the TEN 1-1-1-3-6, the card slot number is …………… (1/ 3/ 6)
21) In SBM configuration, IOP and ADP are directly connected to …………………………… (TU/ TSU/ BPU)
22) In the normal working of BPU, …………………………… is active.
(MU-0, MU-1/ MU-0 & MU-1)
III. Say ‘TRUE’ or ‘FALSE’; if ‘FALSE’, correct the underlined portion:
1) It is possible to login to ‘root’ account from any terminal connected to the IOP.
2) The individual cards in each IOP are duplicated.
IV. Answer the following questions:
1) List the major functions performed by IOP.
2) Mention the different RUN LEVELS of IOP.
3) Name the software deliverables required for Software installation in IOP.
4) The three racks of a C-DOT SBM RAX are shown below. Complete the diagram showing the different TUs and concentration. Also note down the ti identities.
5) Write down the Card Slot No. of the following PCBs:
a) ANNC: b) TTC:
c) TGA-0: d) TGA-1:
e) MFC1: f) MFC2:
g) MFC3: h) MFC4:
i) CPU-0: j) CPU-1:
6) Names of few Switch Units are given below. Indicate the PCBs that constitute them:
a) TI : b) BP :
c) BMS : d) MU :
e) TSC :
7) An alarm message displayed in OOD terminal is shown below.
Now answer the following questions:
i) What is the type of alarm?
ii) Name the Class of this alarm.
iii) Which is the unit affected?
iv) Does this message correspond to a newly reported alarm?
BSNL C-Dot
1) The destination of Signalling Cables is given in P/Q/R/S/T format. Here, P denotes ……………………………………
2) The MDF Cables used for connecting Subscriber lines consists of 64 pairs divided into …………… bunches of ………………… pairs each.
3) To carry out Exchange Side (Signalling + CODEC) tests of a Subscriber Line, Test Set No: ………………… is used.
4) When one copy of BMS goes faulty in a Base Module, the class of alarm generated is …………………………………
5) The Subscriber priority assigned by the system for CCB-STD line is …………
6) A Trunk Group may be identified by a number between …………… & ………………
7) A trunk circuit is identified by the ………………… designating the port at which the circuit is connected to the Exchange hardware.
8) TGP-CAT may be a number between ……………… and ……………………
9) Not more than ……………… TENs can be added to a TGP by a single command.
10) In a TU, time slot ……………………… is used as HDLC message link with BPU.
11) The Announcement Card (ANNC) provides …………… different stored announcements.
12) TTC is located in Slot No: …………… in TU ……………… in the SBM switch.
13) The 128 terminals in a TU are scanned by the SPC during a period of ……… ms.
14) SCIC card in TSU is similar to TIC card hardware and software-wise.
15) IOP is used as the …………………………………… in C-DOT DSS.
16) IOM consists of two similar switch units, namely, ……………… and …………………
17) Operating System used in IOP is ……………………
18) The Link speed of IOP-BP/AP link is …………………… and that of IOP-IOP link is ………………………
19) The BPU hardware when used in AM is called …………………………… and when used in CM is called …………………………………
20) In SBM configuration, BPU is connected to ………………… , …………………… and ………………………………… through HDLC links.
21) ……………………………… is the message transfer point in Base Module.
22) BP communicates with other processors like TIC, SCIC, TSC, TGA, ANNC, MFC through ……………………………………
23) BMS is housed in ………………………………… frame.
24) In MBM configuration, BPU is connected only to ………………………………………
25) In MBM configuration, IOP and ADP are connected to ………………………………
26) In C-DOT DSS MAX, ……………………… is the basic growth unit.
27) The LCC interfaces up to ……………… subscribers.
28) A Terminal Group (TG) consists of ……………… Terminal Cards.
29) In a TU, there can be a maximum of ……………… Terminal Groups (TG).
30) TIC is an ………-bit microprocessor Controller Card.
31) The two types of analog trunk cards are ……………………… & ……………………………
32) TSU receives …………………… channels from each TU.
33) In APU, ………………… Central Message Switches (CMS) are housed.
34) The I/P supply to PSU-II is …………………… and it generates secondary voltages like ……………… , …………………… , …………………… & ……………………
35) If BMS-0 goes faulty in the Base Module, a ………………… Alarm is generated.
II. Choose the correct answer from the brackets:
1) ………………… is the heart of the SBM. (ANNC/ TIC/ BP)
2) There are ………………… Test Access relays in an LCC. (2/ 4/ 8)
3) A maximum of ……………… Terminal Cards can be provided in a TU. (8/ 16/ 24)
4) The signaling information from the terminations are processed by …………… card. (TIC/ TUI/SPC)
5) A TIC controls ………………… Terminal Groups. (2/ 4/ 8)
6) A maximum of ………………… Digital Trunk Systems can be provided in a DTU. (4/ 8/ 16)
7) A maximum of ………… MFC cards can be provided in C-DOT SBM RAX. (4/ 3/ 8)
8) All the tones required for the Exchange are generated by ………………… card. (ANNC/ MFC/ TGA)
9) …………………………… acts as a Message Transfer Point between BP and different controllers. (BP/ BMS/ MU)
10) The Master Controller in the SBM is ………………… (BPU/ TSU/ TIC)
11) The maximum concentration permissible in C-DOT MAX is …………………………… (3:1/ 4:1/ 8:1)
12) The OOD terminal is connected to the ……………… (BP/ TS/ IOP)
13) When one of the IOPs goes out of service, …………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
14) When ANNC goes out of service, …………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
15) When any PSU card failure happens, ………………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
16) When Battery-Low condition is encountered, …………………… alarm is reported. (Non-urgent/ Urgent/ Critical)
17) To find out the status of all Switch Units (SWU) in the system, ……………………… command is used.
18) In BPU and TSU, the PSUs used are of type …………………… (I/ II/ III)
19) From each LCC slot, ……………………… pairs of wires are to be extended to MDF. (8/ 16/ 24)
20) In the TEN 1-1-1-3-6, the card slot number is …………… (1/ 3/ 6)
21) In SBM configuration, IOP and ADP are directly connected to …………………………… (TU/ TSU/ BPU)
22) In the normal working of BPU, …………………………… is active.
(MU-0, MU-1/ MU-0 & MU-1)
III. Say ‘TRUE’ or ‘FALSE’; if ‘FALSE’, correct the underlined portion:
1) It is possible to login to ‘root’ account from any terminal connected to the IOP.
2) The individual cards in each IOP are duplicated.
IV. Answer the following questions:
1) List the major functions performed by IOP.
2) Mention the different RUN LEVELS of IOP.
3) Name the software deliverables required for Software installation in IOP.
4) The three racks of a C-DOT SBM RAX are shown below. Complete the diagram showing the different TUs and concentration. Also note down the ti identities.
5) Write down the Card Slot No. of the following PCBs:
a) ANNC: b) TTC:
c) TGA-0: d) TGA-1:
e) MFC1: f) MFC2:
g) MFC3: h) MFC4:
i) CPU-0: j) CPU-1:
6) Names of few Switch Units are given below. Indicate the PCBs that constitute them:
a) TI : b) BP :
c) BMS : d) MU :
e) TSC :
7) An alarm message displayed in OOD terminal is shown below.
Now answer the following questions:
i) What is the type of alarm?
ii) Name the Class of this alarm.
iii) Which is the unit affected?
iv) Does this message correspond to a newly reported alarm?
BSNL C-Dot
Labels: C-DOT DSS MAX